| Sign In | Join Free | My chinaqualitycrafts.com |
|
Brand Name : RUSEN
Model Number : PCS-A150-MG
Certification : IEC/EN 62109-1/-2, EN 62477-1, IEC/EN 61000-6-2/-6-4, EN 50549-1/-10, NRS 097-2-1:2017 ASGC, GB/T 34120, GB/T 34133, CGC-R46103:2018A, PTPIREE REV1.2: 2024 TYPE B
Place of Origin : China
MOQ : 1pcs
Price : Negotiable
Payment Terms : T/T
Supply Ability : 1000
Delivery Time : 3-30days
Model : PCS-A150-MG
Power Rating : 150KW
Max Efficiency : 97.1%
Operating Temperature Range : -30 ~ 55℃
Battery Compatibility : Li-ion / User-defined
Rated Battery Voltage : 420-850V
Cooling Method : Automatic
Input Voltage Range : 50/60Hz
PV INPUT DC voltage, current : 420-850V
Communication InterfaceInterface : RS485/Wifi/GPRS/CAN/TCP/IP
Certifications : IEC/EN 62109-1/-2, EN 62477-1, IEC/EN 61000-6-2/-6-4, EN 50549-1/-10, NRS 097-2-1:2017 ASGC, GB/T 34120, GB/T 34133, CGC-R46103:2018A, PTPIREE REV1.2: 2024 TYPE B
Warranty : 5 years
• Adopting a compact architecture to achieve high-power integration within a unit volume, suitable for space limited scenarios, and balancing device miniaturization and high-power output requirements.
• Dual backup of critical circuits and power supply, automatic switching in case of failure, coupled with intelligent thermal management system, ensures long-term stable operation without interruption.
• Integrating efficient topology technology and energy optimization algorithms to reduce energy loss and improve energy utilization in scenarios such as energy storage grid connection and industrial power supply.
| Model | PCS-A150-MG |
| DC(battery) | |
| Voltage range (V) | 420~850 |
| Max. current (A) | 405 |
| AC(on-grid) | |
| Max. output power (kW) | 165 |
| Rated output power (kW) | 150 |
| Rated voltage (V) | 400 |
| Voltage range (V) | 320~460 |
| Rated current (A) | 216 |
| Max. output current (A) | 238 |
| Rated frequency (Hz) | 50/60 |
| Frequency range (Hz) | 45~55 / 55~65 |
| THDi | <3% |
| Power factor | 1leading~1lagging(settable) |
| Grid type | 3W+N+PE |
| AC(off-grid) | |
| Rated voltage (V) | 400 |
| THDu | <1% Linear <5% nonlinear |
| Rated frequency (Hz) | 50/60 |
| Overload capacity | 110% long-term |
| General data | |
| Max. efficiency | 97.1% |
| Ingress protection | IP21 |
| Noise emission (dB) | <70 |
| Operating temperature (℃) | -30 ~ +55 |
| Cooling | Forced air |
| Relative humidity | 0 ~95% non-condensing |
| Max. operating altitude (m) | 5,000(>3,000 derating) |
| Dimension W*D*H (mm) | 800*800*1,900 |
| Weight(kg) | 1057 |
| Self-consumption | <0.5% |
| On/ off grid switching | Automatic |
| Display and communication | |
| Display | LCD touch-screen |
| BMS communication | RS485, CAN |
| EMS communication | RS485, TCP/IP |
| Certificates | IEC/EN 62109-1/-2, EN 62477-1, IEC/EN 61000-6-2/-6-4, EN 50549-1/-10, NRS 097-2-1:2017 ASGC, GB/T 34120, GB/T 34133, CGC-R46103:2018A, PTPIREE REV1.2: 2024 TYPE B |
|
|
150KW Built-in Isolation Transformer Power Conversion System for Impact Loads Images |